Does VExUS predict AKI?
VExUS was built to measure systemic venous congestion at the bedside, on the idea that venous pressure transmitted back to the kidney contributes to acute kidney injury. Here is what the main studies found.
The original study
Beaubien-Souligny and colleagues scanned 145 patients after cardiac surgery and tested five ways of combining the IVC with hepatic, portal and intrarenal Doppler. The version now known as VExUS performed best. Severe congestion (grade 3) was strongly associated with later AKI, with a hazard ratio of about 3.7, and was highly specific for it (Beaubien-Souligny 2020).
Studies since
- General ICU. In a single-center ICU cohort, abnormal hepatic and portal vein Doppler were associated with major adverse kidney events at 30 days (Spiegel 2020).
- Cardiorenal syndrome. In a small prospective cohort, higher VExUS grades were associated with AKI, and falling grades with decongestion tracked improving renal function (Bhardwaj 2020).
- Heart failure. Discontinuous intrarenal venous flow predicted worse outcomes, independent of other markers (Iida 2016).
- Mixed ICU, multicenter. In a general ICU population, significant congestion by VExUS was uncommon at admission and was not associated with AKI (Andrei 2023).
How to read this
VExUS looks most useful where venous congestion is a plausible cause of kidney injury: after cardiac surgery, in heart failure and cardiorenal syndrome, and in patients receiving large volumes of fluid. In unselected ICU patients, where most AKI has other causes, it has not shown the same signal. The studies are mostly small and observational, and there are no large trials showing that acting on VExUS changes outcomes.
What it can and cannot tell you
- It measures venous congestion, the back pressure in the venous system. It is not a measure of total body volume or of fluid responsiveness.
- A high grade is a reason to question further fluid and to consider decongestion, in context with the rest of the exam.
- A normal grade does not mean a patient needs fluid.
- Following the grade over time can show whether decongestion is working (Rola 2021).
See how each part is graded: IVC, hepatic vein, portal vein, intrarenal vein.
Common questions
What is a normal hepatic vein Doppler waveform?
The systolic (S) wave is larger than the diastolic (D) wave, both directed toward the heart, with a small reversed A wave after atrial contraction. S smaller than D is mildly abnormal in VExUS, and a reversed S wave is severely abnormal.
How do you calculate portal vein pulsatility?
Pulsatility fraction = (Vmax − Vmin) / Vmax × 100. Under 30% is normal, 30 to 49% is mildly abnormal, and 50% or more is severely abnormal in VExUS.
What IVC size is used in VExUS?
2 cm. Under 2 cm is grade 0 and the Doppler views are not graded. At 2 cm or more, the hepatic, portal and intrarenal patterns decide grades 1 to 3.
Does VExUS predict acute kidney injury?
In cardiac surgery patients, severe VExUS congestion was strongly associated with later AKI. Results in heart failure and cardiorenal syndrome are similar, but a multicenter general ICU study found no association, and no trials yet show that acting on VExUS improves outcomes.
Practice reading these waveforms. The Venous Congestion Trainer plays live hepatic, portal and intrarenal Doppler with an ECG, lets you change each pattern and the IVC, and quizzes you on random cases with an answer key.
Related guides
References
- Beaubien-Souligny W, Rola P, Haycock K, et al. Quantifying systemic congestion with point-of-care ultrasound: development of the venous excess ultrasound grading system. Ultrasound J. 2020;12:16.
- Spiegel R, Teeter W, Sullivan S, et al. The use of venous Doppler to predict adverse kidney events in a general ICU cohort. Crit Care. 2020;24:615.
- Bhardwaj V, Vikneswaran G, Rola P, et al. Combination of inferior vena cava diameter, hepatic venous flow, and portal vein pulsatility index: Venous Excess Ultrasound Score (VEXUS Score) in predicting acute kidney injury in patients with cardiorenal syndrome: a prospective cohort study. Indian J Crit Care Med. 2020;24(9):783-789.
- Andrei S, Bahr PA, Nguyen M, Bouhemad B, Guinot PG. Prevalence of systemic venous congestion assessed by Venous Excess Ultrasound Grading System (VExUS) and association with acute kidney injury in a general ICU cohort: a prospective multicentric study. Crit Care. 2023;27:224.
- Iida N, Seo Y, Sai S, et al. Clinical implications of intrarenal hemodynamic evaluation by Doppler ultrasonography in heart failure. JACC Heart Fail. 2016;4(8):674-682.
- Rola P, Miralles-Aguiar F, Argaiz E, et al. Clinical applications of the venous excess ultrasound (VExUS) score: conceptual review and case series. Ultrasound J. 2021;13:32.